Within the **XProtect Start Client** we see the **Paxton Net2** door states, this is shown in both the **XProtect Access** tab and within **XProtect Maps**.
If you don't use the standard **Paxton Net2 Plus** panel with a PSU some monitored door states will be shown in **XProtect Access**.
Tamper Detected in Paxton is generated either by the panel tamper connector or a door contact where the door has been forced.
In the Paxton API even when not wired the Tamper, Power Supply and Door Contact all provide a fault state as a N/C circuit is expected.
![[z_img/38f33fca8504b456ad7800f94921a362_MD5.jpeg]]
To remove the Tamper, either reinstate the door in Paxton, this will clear a door forced tamper alarm. Otherwise put a physical wire loop over the tamper switch input (Red). The same can be done for the Power Supply Error (Blue).
![[z_img/f36837452b31e11992d8b5f07e0abf08_MD5.jpeg|450]]
## v2.0.12 (Alarm overrides)
In this release we are testing a way to override / ignore each of the monitored Paxton Net2 plus states individually. More information will be provided once we have a full release.