#### Version 1.9.1 >
![[z_img/c88637dce7638eb3b32264ee5d5d5d58_MD5.jpg|250]]
# Prerequisites
## Software
### ORBNET Systems
- Installation software for MAP 5000 plugin
### Bosch
- MAP 5000 Panel with OII interface enabled
### Milestone XProtect
- XProtect version 2014 or later
- Compatible product (see information bellow)

## Hardware
- Windows 64 bits
- IP connection between XProtect and MAP 5000 panel
## Licenses and Access Codes
- ORBNET activation license for the MAP 5000 plugin to go beyond 30 days
- Access codes of a XProtect administrator account
- Access codes of a MAP 5000 OII enabled user account
# MAP 5000 plugin installation
Start by running the provided installer “`MAP5000 Plugin for XProtect Setup vX.X.X.msi`” on the server hosting the XProtect Management server.
1. Press next and agree to the license agreement.
2. The installer will prompt you to restart the “XProtect Event Server” service.

# License activation
The installer comes with a 30 day trial. Please export the license request and send it to us if you want to activate your product.
Each panel can be licensed individually.
Please restart the Event Server after making any changes here.

# MAP 5000 plugin configuration
## Alarm systems
Now that the plugin is installed and the licensed, the next step is to synchronize it with the MAP 5000 panel.
Right click on AlarmSystems -> Add New … (Ctrl+N)
Once the fields have been filled correctly, hit the refresh configuration button and the plugin will automatically retrieve all the items from the alarms system and assign icons to each point according it’s type.
The base license is valid for a single Alarm system. The license price is determined by the number of alarm systems to be connected

### MAP5000 Alarm System name
This field lets you decide that name that you give to your alarm system. Useful when multiple alarm systems are added to a single installation.
### MAP5000 IP
The IP address of the MAP5000 panel. We advise using a static IP.
### MAP5000 Username
The username of a OII enabled user (3-digit number). Instructions on how to enable a user to use the OII interface are found in “MAPOpenIntrusionInterface_ApplicationNotes.pdf”.
### MAP5000 Password
The password of the OII enabled user (6-digit number). The OII user can be tested with a web browser by entering the following url: https://<ip_of_MAP5000_panel>/config
If you get a page showing a large amount of tags and id numbers, then it works.
### Related cameras
Clicking this will open a dialog box that lets you choose cameras to be linked to the alarm panel. In the event of an incident related to the panel (see section on events/alarm), these cameras will be show up with the alarm. Cameras can also be selected for each individual point.
### Refresh Icons
This will reset all point item icons to their default icons according to their type.
### Refresh Configuration
Refreshing the configuration is required every time modifications are done on the MAP5000 panel. The configuration tool will check for new, modified and deleted items and keep the same settings and icons for items that have the same ids.
**Global Authorized Commands**
For each Alarm Panel, you can set whether or not XProtect Smart Client users are allow to:
- Arm Area
- Disarm Area
- Acknowledge alarm
- Silence alarm
- Enable point/device
- Disable point/device
- Bypass Point
- Un-Bypass point
- Activate device
- Deactivate device
- Turn output ON
- Turn output OFF
## Areas
The Areas sub-section provides information on the selected area, a dialog to modify the user rights for each of the areas commands, and some testing buttons.
### Area name
he name of the area.

### SSID
The unique SSID that belongs to this area.
### Parent
The parent alarm system name of this item
## Main devices

The Main devices section provides information on selected main devices and allows instructions to be entered for each type of alarm that can happen on a main device. These instructions will show up when double clicking on an alarm in XProtect’s XProtect Smart Client.
Cameras can be selected to be displayed in case of an alarm and commands are available to enable/disable or activate/deactivate the main device. These commands only work on devices like the touchscreens that can accept on/off commands.
## Points

The points section provides information on selected points, a button to choose an icon that will be displayed on the alarm maps and allows instructions to be entered for each type of alarm that can happen on a point. These instructions will show up when double clicking on an alarm in XProtect’s XProtect Smart Client.
Cameras can be selected to be displayed in case of an alarm and commands are available to enable/disable or activate/deactivate the point/output.
If multiple alarm systems are connected, the devices will stack as shown above. Best practice is to name the important devices such as LSN gateways and O/I modules in alphanumeric order in so that they can easily be found among the others.
# Alarm definitions
Due to the large amount of possible alarms and the possibility to add instructions to each alarm type, an alarm definition must be created for each kind of alarm. You can also exclude some items by only selecting the items you want.

The Missed Events alarm will be triggered if the plugin has detected that a message/incident from the MAP5000 panel has been skipped. This can happen if the Event Server is swamped or if an excessive number of packets are being sent from the MAP5000 alarm system.
# Roles
If using any account that is not part of XProtect Administrators Role, the “Read” and “Manage” checkboxes must be checked for the corresponding items to be respectively visible and triggerable. If one would like to have a particular point be visible for a specific user, that point, and all of its parent items must be checked.
# Rules
Custom rules can be configured (XProtect Corporate) to trigger some commands directly on the MAP5000 panel. Events from the MAP5000 panel can also be used to trigger events and send emails.
Here are the currently supported commands and usable events:

# XProtect Smart Client
## Configuration
Start by adding a Map into a XProtect Smart Client view.
- Go in Setup mode and create a new View.
- Drag & Drop the “Map” item from the System Overview panel into the new View you have created.

- Select an image that you want to use as a Map.
- Once you have a map created, you can start adding the MAP5000 items to the map by opening the toolbox, clicking the MIP plugins icon and drag & dropping the desired elements onto the map.
## Color code and icons
The MAP5000 items on the map are dynamic and intractable. A variety of commands and visual information is available to supervise the system.

### All alarm point icons

## Area commands

Areas from the MAP5000 panel have 4 commands and status details.
### Silence
Will cut the siren(s) related to this area in case of alarm.
### Arm
Arms the selected area, if no incidents or active points.
### Disarm
Disarm the selected area, if allowed.
### Clear incidents
Clears all incidents related to selected zone.
### Status Details
Information on all points and incidents related to that area

## Point commands
Points from the MAP5000 panel have 5 commands and status details.

### Silence
Will cut the siren(s) related to this point in case of alarm.
### Bypass
Bypasses the point if allowed. The alarm system will no longer consider the state changes of this point. Useful for arming an area that has a faulty detector.
### Unbypass
If allowed, the points mode is returned to normal.
### Activate output
Activates the output (point must be of type “Output”).
### Deactivate output
Deactivates the output (point must be of type “Output”).
### Status Details
Information on the point showing which area it is related to, which alarm system it is related to and what state it is in.
