## Interconnect Site
#### Prerequisites
- Central XProtect Corporate system
- Remote XProtect system connected to Central site via Interconnect.
- Alarm Definitions created
REF: [Configure your central site to respond to events from remote sites](https://doc.milestonesys.com/en-US/bundle/doc1040_2025r3/page/content/feature_flags/ff_interconnectedproducts/mc_configureyourcentralsitetorespondtoeventsfromremotesites.htm?tocpath=XProtect+VMS+products%7CXProtect+VMS+administrator+manual%7CConfiguration%7CMilestone+Interconnect%7C_____6) - Milestone Systems
- Create a `User Defined Event` for each alarm you want to trigger on the **Corporate Central Site**.

- For the `Alarm Definition` created on the remote **Interconnect** site add the `User Defined Event` as the `Event triggered`.

- *Alternatively* use a Rule to trigger the User Defined Event when the event in question is triggered.

## Central Corporate Site
- On the **XProtect Corporate site**, Add any `Events` you want to use from the remote **Interconnect site**. These events show with the Hostname of the remote **Interconnect system** before them.

- Restart the **XProtect Event Server** on the **Corporate** central site this will bring the new `Events` into `Rules` and the `Alarm Definitions` from the remote **Interconnected site**.
- Create and `Alarm Definition` with a `Hardware Event`, find the new `Event` from the **Interconnect site**. Select the **Interconnect site** as the Source.

- ==*Alternatively*== in a `Rule` add the `Hardware Event`, select the **Interconnect site** as the `Source`.

Now when the `Event` is triggered you will see the `Alarm Definition` be triggered on both the **Remote Interconnect site** and the **Central Corporate site**.